Philips Trilogy EV300 Ventilator
The Philips Trilogy EV300 delivers full hospital-grade ventilation in a 13.8-pound package that you can actually move between units without calling transport.
Quality Management
Facility & Processes
Biomedical Technicians
About the Philips Trilogy EV300 Ventilator
The Philips Trilogy EV300 delivers full hospital-grade ventilation in a 13.8-pound package that you can actually move between units without calling transport. Unlike traditional ICU ventilators, it runs invasive and noninvasive modes equally well, handling everything from post-op recovery to emergency transport with the same hot-swappable battery system.
The AVAPS-AE auto-titration adjusts pressure settings in real time, which means less manual tweaking during patient transitions. You’ll get continuous SpO2 and EtCO2 monitoring without adding separate modules, and the 8-inch touchscreen keeps critical parameters visible even when you’re troubleshooting at 2 AM. Worth noting: the WiFi connectivity pushes data directly to Philips monitors, so your documentation stays current without extra steps.
Bottom line, 15 hours of battery runtime covers most transport scenarios, and the compact footprint won’t crowd your already tight OR or recovery spaces.
Key Features
- Invasive and noninvasive ventilation for patients 5.5 lb and above
- Pressure capability up to 60 cmH2O with AVAPS-AE auto-titration
- Hot-swappable batteries provide up to 15 hours operation
- Integrated SpO2 and EtCO2 monitoring capabilities
- 8″ color touchscreen with intuitive navigation
- Bluetooth and WiFi connectivity with Philips monitor integration
Specifications for Philips Trilogy EV300 Ventilator
Weight
- Weight: 13.8 lbs (6.3 kg) with hot-swappable battery
Sizes
- Dimensions: 7.6″ D x 11.25″ W x 9.65″ H (19.3 cm D x 28.6 cm W x 24.5 cm H)
- Screen Dimensions: 8″ (20.32 cm)
Capacity
- Patient Range: Patients 5.5 lb and above
- Pressure Range: Up to 60 cmH2O
Ventilation Modes
- A/C-PC: Assist control (pressure control)
- A/C-VC: Assist control (volume control)
- CPAP: Continuous positive airway pressure
- PSV: Pressure support ventilation
- S/T: Spontaneous/timed ventilation
- SIMV-PC: Synchronized intermittent mandatory ventilation (pressure control)
- SIMV-VC: Synchronized intermittent mandatory ventilation (volume control)
Battery
- Runtime: Up to 15 hours’ hot-swap battery (nominal runtime per IEC method)
- Charge Time: Detachable battery and internal battery charge time 0% to 80% in 2.5 hours, 0% to 100% in 3.5 hours
Connectivity
- Interfaces: Bluetooth, WiFi, Philips monitor connectivity
Illumination
- Display Type: 8″ color touchscreen
Intended Use
- Applications: Intra-hospital ventilation and patient transport support for invasive and noninvasive ventilation