Hamilton T1 Transport Ventilator
The Hamilton T1 Transport Ventilator runs on its own high-performance blower, eliminating the compressed gas dependency that limits most transport units.
Quality Management
Facility & Processes
Biomedical Technicians
About the Hamilton T1 Transport Ventilator
The Hamilton T1 Transport Ventilator runs on its own high-performance blower, eliminating the compressed gas dependency that limits most transport units. You get full ICU-level ventilation across adult, pediatric, and neonatal patients without worrying about oxygen supply during transfers.
The closed-loop ASV mode automatically adjusts to patient needs while you focus on transport logistics. Worth noting: the anti-reflective touchscreen stays readable in ambulance lighting, and all patient data remains visible during bumpy rides thanks to the shock-resistant housing.
At 14.3 pounds with battery, it’s light enough for one person to handle but tough enough for helicopter transport. The hot-swappable battery system gives you over 9 hours of runtime, so long-distance transfers don’t require power planning.
Key Features
- Independent blower operation eliminates compressed gas dependency
- Closed-loop ASV plus full pressure, volume, and NIV modes
- Over 9 hours battery life with hot-swappable extension
- Water and shock resistant for all transport environments
- Anti-reflective color touchscreen readable in any lighting
- Full ICU ventilation for adult, pediatric, and neonatal patients
Specifications for Hamilton T1 Transport Ventilator
Ventilation Modes
- Modes: Closed-loop control: ASV; Pressure: PCV+, PSIMV+, SPONT, APRV, DuoPAP; Volume: (S)CMV+/APVcmv, SIMV+/APVsimv; Noninvasive: NIV, NIV-ST, nCPAP, nCPAP-PC
Sizes
- Display: 8.4 in, TFT, color, backlit, touchscreen, night-vision compatibility
Weight
- Weight: 14.3 lb (with one battery and handle); 12.3 lb (without battery or handle)
Compatibility
- Main Patient Outlet: ISO 5356-1; 22M/15F
- Oxygen Inlet: DISS or NIST male
- Low Oxygen Inlet: CPC quick coupling, 3.2 mm ID
Capacity
- Tidal Volume Range: 20 ml to 2,000 ml
- Optional Neonatal Tidal Volume: 2 ml to 300 ml
Physical Dimensions
- Height (with handle raised): 11.8 in
- Height (with handle lowered): 9.4 in
- Width: 12.2 in
- Depth: 8.3 in
- Mobile Stand Height: 53.5 in
- Mobile Stand Width: 24.8 in
Environment
- Operating Temperature: -15°C to 50°C (adult); -15°C to 40°C (neonatal)
- Operating Humidity: 5% to 95% non-condensing
- Altitude: Up to approx. 25,000 ft, 1,000 to 376 hPa (adults); up to 13,120 ft, 1,000 to 600 hPa (neonates)
- Storage Temperature: -20°C to 60°C
- Storage Humidity: 10% to 95% non-condensing