Call Us Today

(502) 244-4444

Certified Refurbished

Hamilton T1 Transport Ventilator

The Hamilton T1 Transport Ventilator runs on its own high-performance blower, eliminating the compressed gas dependency that limits most transport units.

New List Price $1.00
Your Savings
DRE Price $1.00

Our equipment specialists are here to help you with your questions.

Hours: Monday – Friday 8AM – 5PM ET

The Hamilton T1 Transport Ventilator runs on its own high-performance blower, eliminating the compressed gas dependency that limits most transport units. You get full ICU-level ventilation across adult, pediatric, and neonatal patients without worrying about oxygen supply during transfers.

The closed-loop ASV mode automatically adjusts to patient needs while you focus on transport logistics. Worth noting: the anti-reflective touchscreen stays readable in ambulance lighting, and all patient data remains visible during bumpy rides thanks to the shock-resistant housing.

At 14.3 pounds with battery, it’s light enough for one person to handle but tough enough for helicopter transport. The hot-swappable battery system gives you over 9 hours of runtime, so long-distance transfers don’t require power planning.

Key Features

  • Independent blower operation eliminates compressed gas dependency
  • Closed-loop ASV plus full pressure, volume, and NIV modes
  • Over 9 hours battery life with hot-swappable extension
  • Water and shock resistant for all transport environments
  • Anti-reflective color touchscreen readable in any lighting
  • Full ICU ventilation for adult, pediatric, and neonatal patients

Ventilation Modes

  • Modes: Closed-loop control: ASV; Pressure: PCV+, PSIMV+, SPONT, APRV, DuoPAP; Volume: (S)CMV+/APVcmv, SIMV+/APVsimv; Noninvasive: NIV, NIV-ST, nCPAP, nCPAP-PC

Sizes

  • Display: 8.4 in, TFT, color, backlit, touchscreen, night-vision compatibility

Weight

  • Weight: 14.3 lb (with one battery and handle); 12.3 lb (without battery or handle)

Compatibility

  • Main Patient Outlet: ISO 5356-1; 22M/15F
  • Oxygen Inlet: DISS or NIST male
  • Low Oxygen Inlet: CPC quick coupling, 3.2 mm ID

Capacity

  • Tidal Volume Range: 20 ml to 2,000 ml
  • Optional Neonatal Tidal Volume: 2 ml to 300 ml

Physical Dimensions

  • Height (with handle raised): 11.8 in
  • Height (with handle lowered): 9.4 in
  • Width: 12.2 in
  • Depth: 8.3 in
  • Mobile Stand Height: 53.5 in
  • Mobile Stand Width: 24.8 in

Environment

  • Operating Temperature: -15°C to 50°C (adult); -15°C to 40°C (neonatal)
  • Operating Humidity: 5% to 95% non-condensing
  • Altitude: Up to approx. 25,000 ft, 1,000 to 376 hPa (adults); up to 13,120 ft, 1,000 to 600 hPa (neonates)
  • Storage Temperature: -20°C to 60°C
  • Storage Humidity: 10% to 95% non-condensing