The VM8 handles continuous monitoring across all patient populations with a single device, switching between adult, pediatric, and neonatal parameters.

New List Price $1.00
Your Savings
DRE Price $1.00

Our equipment specialists are here to help you with your questions.

Hours: Monday – Friday 8AM – 5PM ET

The VM8 handles continuous monitoring across all patient populations with a single device, switching between adult, pediatric, and neonatal parameters without needing separate equipment. Worth noting: it stores 96 hours of trend data locally, so you’re not losing patient history during transfers or system downtime.

Multi-parameter monitoring includes 3- or 5-lead ECG, Philips SpO2 technology, and multiple NIBP modes (manual, interval, and STAT). The bright display shows up to four waveforms simultaneously, and fixed keys keep operation straightforward during critical moments. Optional Microstream EtCO2 works for both intubated and non-intubated patients.

At 7.7 pounds with a 4-hour battery life, it moves easily between units with the integrated carrying handle and bed rail hanger. Data outputs via HL7 through the Ethernet port, and USB connectivity allows for software upgrades without service calls.

Key Features

  • Multi-parameter monitoring for adult, pediatric, and neonatal patients
  • 96-hour trend storage with HL7 data output
  • Bright display with up to four waveforms
  • Philips SpO2 technology with full sensor range
  • Multiple NIBP modes including STAT function
  • 4-hour battery with portable design
  • Optional Microstream EtCO2 and barcode scanner
  • USB port for software upgrades

Contents

  • Patients: Adult, Pediatric, Neonatal

Data Output

  • Format: HL7 via Ethernet port

Battery

  • Type: Lithium ion, 10.8-11.1 V
  • Operating Time: 4 hours with continuous monitoring and NIBP every 15 minutes

Dimensions

  • Width: 12.6 in (32 cm)
  • Height: 10.6 in (27 cm)
  • Depth: 6.9 in (17.5 cm)

Weight

  • Weight: 7.7 lbs (3.5 kg)

Screen

  • Type: SVGA TFT-AM LCD
  • Size: 10.4 in (26.4 cm)

NIBP

  • Method: Oscillometric using stepwise deflation pressure
  • Adult Measurement Range: Systolic: 30-270 mmHg; Diastolic: 10-245 mmHg; MAP: 20-225 mmHg; Pulse Rate Range: 40-300 bpm
  • Pediatric Measurement Range: Systolic: 30-180 mmHg; Diastolic: 10-150 mmHg; MAP: 20-160 mmHg; Pulse Rate Range: 40-300 bpm
  • Neonatal Measurement Range: Systolic: 30-130 mmHg; Diastolic: 10-100 mmHg; MAP: 20-120 mmHg; Pulse Rate Range: 40-300 bpm
  • Blood Pressure Accuracy: Maximum Standard Deviation: 8 mmHg; Maximum Mean Error: ±5 mmHg
  • Pulse Rate Accuracy: 40–100 bpm: ±5 bpm; 101–200 bpm: ±5% of reading; 201–300 bpm: ±10% of reading

IBP

  • Measurement Range: ABP/CVP/PAP: -40 – 360 mmHg
  • Accuracy: Overall accuracy (including transducer): greater of ±4 mmHg or ±4%

SpO2

  • Measurement Range: 0-100%
  • Note: Accuracy depends on sensor

ECG

  • Leads: 3- or 5-lead
  • Heart Rate Range: 15–300 bpm
  • Heart Rate Accuracy: greater of ±1% or ±5 bpm
  • Additional: Arrhythmia analysis

CO2

  • Range: 0–150 mmHg
  • awRR Respiration Rate Range: 0-150 breaths per minute
  • awRR Accuracy: ±1 bpm (0-70 bpm); ±2 bpm (71-120 bpm); ±3 bpm (121-150 bpm)
  • Accuracy: 0–38 mmHg ±2 mmHg; 31–150 mmHg ±(5% of reading + 0.08% per mmHg above 38 mmHg)

Temperature

  • Mode: Continuous
  • Method: Esophageal, rectal, or skin
  • Range: 25-45°C (77-113°F)
  • Accuracy: ±0.1°C (±0.2°F)

Intended Use

  • Settings: Hospital and other clinical care environments for adult, pediatric, and neonatal monitoring