DRE Echo CO2 Capnograph Monitor
- SKU: 60129CO2RS
The Zimmer A. T. S 4000 calculates individualized pressure settings for each patient rather than using standard pressure protocols.
ISO 13485 Certified
Quality Management
FDA Registered
Facility & Processes
Factory-Trained
Biomedical Technicians
Our equipment specialists are here to help you with your questions.
Hours: Monday – Friday 8AM – 5PM ET
About the DRE Echo CO2 Capnograph Monitor
The DRE Echo CO2 provides cost-effective SPO2 and CO2 monitoring with accuracy and durability.
The Echo CO2 ensures effective capnography monitoring for intubated and non-intubated patients for continuous long term monitoring. It is tailored for mechanically ventilated and non-intubated patients.Features:
- 5.7 inch high resolution display for easy reading
- Lightweight, portable design and user-friendly interface for easy operation
- Flexible configurations to meet different clinical needs
- Standard SpO2
- PR measurement
- Respironics Loflo sidestream and CAPNOSTAT 5
- ETCO2 mainstream measurement
- Real-time parameters measurement display with trend table for easy reviewing
- Built-in rechargeable Lithium-ion battery for
- 10 hours continuous working
- Powerful storage capacity
- Bi-directional communications with central station by wired or wireless network
- Nurse call
Specifications for DRE Echo CO2 Capnograph Monitor
Physical Specifications
- Size: 200.8mm (L) x 241mm (H) x 189 mm (D)
- Weight: 3 kg
- Display: 5.7 inches
- Color TFT resolution: 640X480
- Power Supply: 100-240 VAC, 50/60HZ
- Pmax=70VA FUSE T 1.6AL
- Battery Type: Lithium-ion
- Voltage: 14.8 V DC Capacitance: 4,400 mAh
- Working period: Color TFT 480min
- Rechargeable period: < 360min
- Thermal Recorder: (Optional)
- Record Width: 48 mm
- Paper Speed: 25mm/s
SpO2
- Measuring Range: 0 ~ 100 %
- Alarm Range: 0 ~ 100 %
- Resolution: 1 %
- Accuracy
- Adult (including Pediatric)
- 2% (70%~100% SpO2)
- Undefined 0~70% SpO2
Neonate
- 3% (70%~100% SpO2)
- Undefined (0~70% SpO2)
Pulse Rate
- Measuring and Alarm Range: 30 ~ 300bpm
- Resolution: 1bpm
- Accuracy: 3bpm
- Data update period: 2s
- ISO 9919
- Respironics CO2
Mainstream
- CO2 Measurement Range
- 0 to 150 mm Hg,0 to 19.7%,
- 0 to 20 kPa (at 760 mm Hg)
- Rise Time
- Less than 60 ms Adult/Infant
- Reusable or Single Patient Use
- Airway Adapter
- CO2 Resolution
- 0.1 mm Hg — 0 to 69 mm Hg
- 0.25 mm Hg — 70 to 150 mm Hg
- CO2 Accuracy
- 0-40 mm Hg — 2 mmHg
- 41 – 70 mm Hg — 5% of reading
- 71 – 100 mm Hg — 8% of reading
- 101 – 150 mm Hg — 10% of reading
- Above 80 bpm — 12% of reading
- CO2 Stability
- Short Term Drift: Drift over four hours shall not exceed 0.8 mm Hg max.
- Long Term Drift: Accuracy specification will will be maintained over a 120-hour period
- Respiration Rate Accuracy
- 1 breath
- Calibration
- No routine user calibration required. An airway adapter zero is required when changing to a different style of airway adapter
- Water Resistance
- IPX4-Splash-proof (sensor head only)
- Shock Impact
- EN60068-2-6 Sinusoidal Vibration
- EN60068-2-27 Shock
- EN60068-2-64 Random Vibration
- Able to withstand repeated 6 foot drops onto tiled floor while operating
Sidestream
- Sample Rate: 50 m/L per minute
- CO2 Measurement Range:
- 0 – 150 mm Hg, 0 to 20 kPa
- (at 760 mm Hg). Barometric Pressure
- supplied by Host
- CO2 Resolution:
- 0.1 mm Hg 0 to 69 mm Hg
- 0.25 mm Hg 70 to 150 mm Hg
- CO2 Accuracy
- 0 – 40 mm Hg 2 mm Hg
- 41 – 70 mm Hg 5% of reading
- 71 – 100 mm Hg 8% of reading
- 101 – 150 mm Hg 10% of reading
- Above 80 bpm 12% of reading
- CO2 Stability
- Short Term Drift: Drift over four hours shall not exceed 0.8 mm Hg max.
- Long Term Drift: Accuracy specification will be maintained over a 120-hour period
- Respiratory Rate Range: 2 to 150 bpm
- Respiratory Rate Accuracy: 1 breath
Sample Cell/Filter
- Proprietary single patient use sample cell and inline filter are integrated with the sample line which eliminates contamination of the internal system
- Nasal Sampling Kits for Non-intubated Patients Adult, pediatric and infant nasal CO2 sampling, nasal CO2 sampling and O2 delivery
- Adult and pediatric nasal/oral CO2sampling, nasal/oral CO2 sampling and O2 delivery
- On-Airway Adapter KITS for Intubated Patients
- Adult/Pediatric with and without dehumidification tubing Pediatric/ Infant, low dead space, with and without dehumidification tubing
- Taper meets ISO 5356-1
- Sample Kit Hours of Use
- Nasal Cannula (all styles) — up to 12 hours
- On-Airway Adapter Kits without dehumidification tubing — up to 12 hours
- Sample Cell Detection
- Insertion automatically turns sampling pump on. Removal automatically turns sampling pump off.
- Water Resistance IPX4 -Splash-proof(when sample cell is inserted in sample cell receptacle)
- Shock Impact IEC TR 60721-4-7 Class 7M3(designed to withstand environments subject to significant vibrations or high shock levels)
- EN60068-2-27 Shock
- EN60068-2-64 Random vibration