DRE Waveline SV15 Patient Monitor
The Waveline SV15 puts four channels of invasive pressure monitoring and full anesthesia gas capability into a 15.
Quality Management
Facility & Processes
Biomedical Technicians
About the DRE Waveline SV15 Patient Monitor
The Waveline SV15 puts four channels of invasive pressure monitoring and full anesthesia gas capability into a 15.6-inch touchscreen package that displays 12 simultaneous waveforms. That’s double the IBP capacity of the SV10 and SV12 models, making it the go-to choice when you need complete hemodynamic monitoring in the ICU, CCU, or OR.
The monitoring suite covers everything from 12-lead ECG with ST-segment analysis to CO2 and anesthesia gas modules. Worth noting: the dual 5000 mAh battery setup delivers 10 hours of runtime, so you won’t lose monitoring during transport or extended procedures. Data storage captures 48 hours of full-disclosure waveforms at one-second resolution.
Connectivity includes dual-band Wi-Fi, Ethernet, and direct integration with MFM-CMS central monitoring systems. The built-in thermal recorder handles three-channel waveform printing, and the touchscreen interface lets you customize waveform colors and display modes for different clinical scenarios.
Key Features
- 15.6-inch Full HD touchscreen displays up to 12 simultaneous waveforms
- Four-channel IBP monitoring, double the capacity of SV10/SV12 models
- Anesthesia gas monitoring
- Complete parameter suite: 12-lead ECG, SpO2, NIBP, RESP, TEMP, IBP, CO, CO2
- 10-hour battery runtime with dual 5000 mAh configuration
- 48-hour full-disclosure waveform storage at 1-second resolution
- Dual-band Wi-Fi plus Ethernet for MFM-CMS network integration
- Advanced NIBP algorithms (iCUFS and iFAST) for all patient populations
Specifications for DRE Waveline SV15 Patient Monitor
Display
- Screen Size: 15.6-inch Color TFT Touchscreen
- Resolution: 1920×1080 (Full HD)
- Max Simultaneous Waveforms: 12
Size
- Dimensions: 15.2″ (W) × 11.3″ (H) × 6.4″ (D)
Weight
- Weight: < 4.9 kg (standard config, excl. battery & accessories)
Power
- AC Power: 100–240V~, 50/60 Hz
- Battery (2× 2500 mAh): ≥ 5 hours runtime
- Battery (2× 5000 mAh): ≥ 10 hours runtime
Monitoring Capabilities
- IBP
- AG Monitoring
- CO2 Modules
- SpO2
- NIBP
- ECG Lead Modes: 3, 5, 6, 12-Lead
Data Management
- Trend Data Storage: 48h @ 1s / 240h @ 1min
- NIBP Storage: 1,200 sets
- Alarm Event Storage: 1,000 sets
- Full Disclosure Waveform: 48 hours
Connectivity
- Wi-Fi: IEEE 802.11a/b/g/n, 2.4 GHz & 5 GHz
Standards
- Ingress Protection: IP22
- Compliance: IEC 60601-1, IEC 60601-1-2, IEC 80601-2-49
Environmental
- Operating Temp: 0°C to 40°C (32°F to 104°F)
- Storage Temp: -20°C to 60°C (-4°F to 140°F)