Call Us Today

(502) 244-4444

New

DRE Waveline Pro Touch-Screen Anesthesia Monitor

Eight simultaneous waveforms on a single 15-inch display means you won’t miss critical changes during complex cases.

New List Price $1.00
Your Savings
DRE Price $1.00

Our equipment specialists are here to help you with your questions.

Hours: Monday – Friday 8AM – 5PM ET

Eight simultaneous waveforms on a single 15-inch display means you won’t miss critical changes during complex cases. The Waveline Pro Touch-Screen Anesthesia Monitor handles everything from basic vitals to advanced hemodynamics without cluttering your workspace with multiple devices.

Motion-tolerant Masimo SET SpO2 monitoring stays accurate even when patients move, while built-in arrhythmia detection catches irregular rhythms automatically. Worth noting: the system stores up to 72 hours of trending data and prints directly from the integrated 3-channel thermal recorder. HL7 compliance means it’ll talk to your existing EMR without custom interfaces.

Two removable batteries plus internal lithium-ion backup keep monitoring continuous during transport. The touch interface responds quickly, and you can configure alarm limits for each case without diving through menu layers.

Key Features

  • 15-inch touch-screen displaying 8 waveforms simultaneously
  • Motion-tolerant Masimo SET SpO2 with arrhythmia detection
  • 3-lead or 5-lead ECG monitoring
  • Built-in thermal recorder with 3-channel printing
  • 72-hour patient data trending and storage
  • HL7-compliant networking via Ethernet and RS-232
  • Triple battery system for uninterrupted monitoring
  • Optional anesthesia gas bench, EtCO2, and invasive BP modules
  • Color-coded alarms with user-configurable limits

Performance

  • Display: 15-inch color touch-screen
  • Trace: 8 waveforms
  • Trend Time: 1 – 72 hour
  • Recorder: Built-in thermal array, 3 channels
  • Record Width: 48 mm
  • Recorder Paper: 50 mm
  • Record Speed: 25 mm/s, 50 mm/s

ECG

  • Input: 5-lead ECG cable and standard AAMI line for connection
  • Lead Choice: I, II, III, aVR, aVF, aVL, V, V1-V6, TEST
  • Gain Choice: x0.5, x1, x2, x4
  • Frequency Characteristic: 0.05 ~ 35 Hz (+3dB)
  • ECG Waveforms: 7 channels
  • Sweep Speed: 12.5, 25, 50 and 100 mm/sec
  • HR Display Range: 30 ~ 300 bpm
  • Accuracy: ±1 bpm or ±1%, whichever is greater
  • Alarm Limit Range Setting: Upper 100 ~ 200 bpm, Lower 30 ~ 100 bpm

RESP

  • Measure Method: RA-LL impedance
  • Range: 0 ~ 120 rpm
  • Accuracy: ±3 rpm
  • Alarm Limit Setting: Upper 6 ~ 120 rpm, Lower 3 ~ 120 rpm

NIBP

  • Measuring Technology: Automatic oscillating measurement
  • Cuff Inflating: <30 s (0 ~ 300 mmHg, standard adult cuff)
  • Measuring Period (AVE): <40 s
  • Mode: Manual, Auto
  • Measuring Interval in AUTO Mode: 2 min ~ 4 hrs
  • Pulse Rate Range: 30 ~ 250 bpm
  • Measuring Range (Adult/Pediatric): SYS 40 ~ 250 mmHg, DIA 15 ~ 200 mmHg
  • Measuring Range (Neonate): SYS 40 ~ 135 mmHg, DIA 15 ~ 100 mmHg
  • Accuracy: Maximum Mean Error ±5 mmHg; Maximum Standard Deviation 8 mmHg

TEMP

  • Range: 25 ~ 50 °C
  • Accuracy: ±0.2°C (25.0 ~ 34.9°C); ±0.1°C (35.0 ~ 39.9°C); ±0.2°C (40.0 ~ 44.9°C); ±0.3°C (45.0 ~ 50.0°C)
  • Display Resolution: 0.1°C
  • Alarm Limit Setting: Upper 0 ~ 50°C, Lower 0 ~ 50°C
  • Channel: 2 channels

SpO2 (Masimo SET)

  • SpO2 Measuring Range: 1 ~ 100 %
  • PR Measuring Range: 25 ~ 240 bpm
  • SpO2 Accuracy (non-motion) Adult/Pediatric: 70–100%: ±2%
  • SpO2 Accuracy (non-motion) Neonate: 70–100%: ±3%
  • SpO2 Accuracy (motion) Adult/Pediatric: 70–100%: ±3%
  • Low Perfusion Performance: >0.02% Pulse Amplitude and % Transmission >5
  • PR Accuracy (non-motion): 25–240 bpm: ±3 bpm
  • PR Accuracy (motion): 25–240 bpm: ±5 bpm

IBP

  • Measurement Range: -50 ~ 300 mmHg
  • Channel: 2 channels
  • Pressure Transducer Sensitivity: 5 µV/V/mmHg
  • Impedance Range: 300 ~ 3000 Ω
  • Transducer Sites: ART, PA, CVP, RAP, LAP, ICP
  • Unit: mmHg/kPa selectable
  • Resolution: 1 mmHg
  • Accuracy: ±1 mmHg or ±2%, whichever is greater
  • Alarm Range: -10 ~ 300 mmHg

EtCO2 (Optional)

  • CO2 Measurement Range: 0 ~ 99 mmHg
  • Accuracy: ±2 mmHg (0 ~ 38 mmHg); 39–99 mmHg ±5% of reading +0.08% per 1 mmHg above 38 mmHg
  • Sampling Rate: 50 ml/min
  • Initialization Time: 30 seconds (typical)
  • Respiration Rate: 0 ~ 150 breaths/min
  • Mode: Adult, Neonate

Cardiac Output (Optional)

  • Measurement Method: Thermodilution Method
  • C.O. Measurement Range: 0.1 to 20 L/min
  • Resolution/Accuracy: C.O. ±5% or ±0.1 L/min, whichever is greater
  • Repeatability: C.O. ±2% or 0.1 L/min, whichever is greater
  • TB, TI Resolution: 0.1

Anesthetic Agents (Optional)

  • Method: Infrared absorption
  • Gas Sorts: Halothane, Isoflurane, Enflurane, Sevoflurane, Desflurane, CO2, N2O, O2 (optional Automatic Agent ID)
  • Measurement Range: Halothane/Isoflurane 0 – 8.5%; Enflurane/Sevoflurane 0 – 10%; Desflurane 0 – 20%; CO2 0 – 10%; N2O/O2 0 – 100%
  • Bias/Accuracy: Halothane/Isoflurane/Enflurane/Sevoflurane/Desflurane: ±(0.15 Vol% + 15% rel.); CO2: ±(0.5 Vol% + 12% rel.); N2O: ±(2 Vol% + 8% rel.); O2: ±3 Vol%

Networking

  • Wireless: Industry standard 802.11b/g
  • Connectivity: Ethernet and RS-232 with open communication protocol
  • Compliance: HL7 compliant

Power

  • AC Power: 100 – 240 VAC, 50/60 Hz
  • Battery: Built-in and rechargeable lithium ion
  • Operating Time: 3+ hours

Environmental

  • Operating Temperature: 5° – 40° C
  • Storage Temperature: -20° – 65° C
  • Humidity Operating: ≤ 80%
  • Humidity Storage: ≤ 80%

Other

  • Other Standard Features: OxyCRG, drug dose calculation, cascading ECG, on-screen NIBP trends (up to 250 readings), user-set defaults, arrhythmia detection, ST segment
  • Condition: New
  • Category: Patient Monitoring
  • Medical Equipment: Anesthesia Monitors
Certified Refurbished