Philips MX8000 IDT 16 CT Scanner
The Philips MX8000 IDT delivers 16-slice imaging with Infinite Detector Technology that maintains detail consistency across all slice thicknesses, unlike.
Quality Management
Facility & Processes
Biomedical Technicians
About the Philips MX8000 IDT 16 CT Scanner
The Philips MX8000 IDT delivers 16-slice imaging with Infinite Detector Technology that maintains detail consistency across all slice thicknesses, unlike conventional detectors that lose resolution at thinner acquisitions. Its 24mm detector coverage captures more anatomy per rotation while the Dynamic Focus System increases spatial resolution by dynamically adjusting the focal spot size during acquisition.
DoseRight protocols automatically adjust current selection and provide real-time dose modulation based on patient anatomy. The short version: you’ll get consistent image quality while reducing radiation exposure. The system reconstructs up to 6 images per second and covers 80cm of anatomy in a single 13-second breath hold, which speeds up your cardiac and trauma protocols considerably.
Both sides of the gantry have full operator controls, so your techs won’t waste time walking around between patients. The 70cm aperture accommodates larger patients while maintaining a 50cm field of view for imaging.
Key Features
- Infinite Detector Technology for consistent detail at all slice thicknesses
- 24mm detector coverage for dose-efficient acquisition
- 0.5-second rotation time with 16-slice capability
- DoseRight ACS and DOM for automatic dose optimization
- Dynamic Focus System for enhanced spatial resolution
- Dual-sided gantry controls for workflow efficiency
- 80cm spiral coverage in single breath hold
- 6.5 MHU tube with 60kW high-frequency generator
Specifications for Philips MX8000 IDT 16 CT Scanner
General
- Type: Multislice
- Slices: 16
- Condition: Refurbished
- Weight: 2100 kg
Gantry
- Maximum Clearance: 70 cm
- Field Of View: 50 cm
Imaging Performance
- Slice Modes: 16 x 0.75 mm; 16 x 1.5 mm; 8 x 3 mm
- Rotation Time: 0.5 seconds (360°)
- Reconstruction Rate: Up to 6 images per second (512 x 512)
- Spiral Coverage: 80 cm in one 13-second breath hold at 1.5 mm slice thickness
Detector / Acquisition
- Detector Coverage: 24 mm total
- Volumetric Scan: Up to 97.5 continuous, bi-directional acquisition
Components
- Generator: 60 kW high-frequency high-voltage generator
- X‑ray Tube: 6.5 MHU high power x-ray tube
- Patient Table Scannable Range: 1570 mm
- Image Display: 21 in CRT
Software / Processing
- Included Functions: Bolus Pro Ultra; Spiral Auto Start; Evolving Image; Ultra High resolution matrices; Zoom and pan; Cine; Multiformat and image graphics
Standards
- Image Archiving: DICOM 3.0 compliant