DRE Neolite Infant Radiant Warmer
The Neolite switches between manual heat control and automatic skin temperature servo-control, letting you adjust thermal management based on patient.
Quality Management
Facility & Processes
Biomedical Technicians
About the DRE Neolite Infant Radiant Warmer
The Neolite switches between manual heat control and automatic skin temperature servo-control, letting you adjust thermal management based on patient condition without swapping equipment. Unlike single-mode warmers, you get real-time display of both set temperature and actual skin temperature simultaneously.
The built-in APGAR timer runs automatically with audio cues at 1, 5, and 10 minutes, while multi-function alarms monitor sensor connectivity, temperature variance, and system status. Worth noting: the heating power indicator shows exactly how hard the unit’s working (0-100%), so you can spot when patients aren’t maintaining temperature efficiently.
The radiation head adjusts to three fixed angles (0°, 30°, 60°) and bed tilts ±15° for positioning flexibility. X-ray cassette slides under the bed, and RS232 output connects to monitoring systems when needed.
Key Features
- Dual control modes: manual and skin temperature servo-control
- Simultaneous set and skin temperature display
- Adjustable radiation head (0°, 30°, 60°) and bed inclination (±15°)
- APGAR timer with automatic 1, 5, 10 minute alerts
- Heating power rate indicator (0-100%)
- Integrated X-ray cassette and RS232 data output
- Complete configuration with sensors, I.V. pole, and accessories
Specifications for DRE Neolite Infant Radiant Warmer
General
- Power Supply: AC110V – 240V/50-60HZ
- Power Input: 700VA
- Temperature Control Range: 25° C – 37° C
- Sensor Precision: ≤0.3° C
- Uniformity of Bed Temperature: ≤2.0° C
Adjustment
- Radiation Head Angles: 0°, 30°, 60°
- Bed Inclination: ±15°
Alarming
- APGAR Timer: Sound indications at 1 min., 5 min., 10 min.
- Audible and Visible Alarm: Indicates the real temperature and cuts off the power supply of heater when necessary
- Over-Temp Alarm: Sounds when skin temperature is >39.5° C
- Deviation Alarm: Indicates when the temperature deviates from the setting temperature by ±1° C
- Sensor Alarm: Activates when the sensor is disconnected, open circuit, short circuit or placed outside of bed
- Power Failure Alarm: Sounds when the unit is turned on but there is no power or if the power cord is disconnected
- System Alarm: Sounds when there is a system malfunction inside the temperature controller
Contents
- Standard Configuration: Radiation head; Temperature controller; Skin temperature sensor; Bed temperature sensor; Infant bed and bed deck; I.V. pole; Tray; Stand
Weight and Dimensions
- Package Gross Weight: 110 kg
- Measurement: 1,270 mm × 810 mm × 1,110 mm
Materials
- Components: Stainless Steel
Compatibility
- Data Output: RS232