Call Us Today

(502) 244-4444

Certified Refurbished

DINAMAP ProCare 400 Vital Signs Monitor

Push-button NIBP measurement with DINAMAP technology gives you accurate readings without the guesswork of manual methods.

New List Price $1.00
Your Savings
DRE Price $1.00

Our equipment specialists are here to help you with your questions.

Hours: Monday – Friday 8AM – 5PM ET

Push-button NIBP measurement with DINAMAP technology gives you accurate readings without the guesswork of manual methods. The ProCare 400 handles spot-check monitoring when you need reliable vitals fast.

Memory stores 25 determinations over 24 hours, so you can track trends without hunting through paper charts. The upside: upgradeable platform means you can add SpO2 and temperature modules when your monitoring needs expand, rather than buying new equipment.

At 5.68 pounds with battery, it moves easily between rooms or mounts on a rolling stand for permanent placement. Water ingress protection handles the reality of clinical environments.

Key Features

  • Push-button NIBP measurement using DINAMAP technology
  • Upgradeable platform for SpO2 and temperature modules
  • Memory stores up to 25 determinations within 24 hours
  • Flexible mounting options for portable or stationary use
  • Water ingress protection for clinical environments

Contents

  • External Power Supply: Included

Capacity

  • Memory: Stores up to 25 determinations within a 24-hour period

Sizes

  • Cuff Sizes: 0; 1; 2; 3; 4

Weight

  • Weight: 5.68 lbs (2.58 kg) with battery

Materials

  • Components: Stainless Steel

Compatibility

  • SpO2 Options: Choice of Masimo SET or Nellcor OxiMax (upgradeable)
  • Temperature Option: IVAC TurboTemp (upgradeable)

Illumination

  • Display Illumination: Conventional; Fiber Optic

Intended Use

  • Patient Populations: Neonatal, Pediatric, Adult
  • Settings: ER, Outpatient Surgery, Endoscopy, GI Lab, Special Procedures, Recovery/PACU, Telemetry, Med-Surg, Labor & Delivery

Blood Pressure

  • Pressure Range: 10 to 290 mmHg (adult/ped); 10 to 140 mmHg (neonate)
  • Accuracy: Meets or exceeds ANSI/AAMI standard SP-10 (mean error ≤5 mmHg, standard deviation ≤8 mmHg)
  • Maximum Determination Time: 120 seconds (adult/ped); 85 seconds (neonates)
  • Overpressure Cutoff: 330 mmHg (adult/ped); 165 mmHg (neonate)
  • Pulse Rate Range: 30 to 200 beats/min (adult/ped); 30 to 220 beats/min (neonate)
  • Systolic Limits: 200 mmHg high, 80 mmHg low
  • Diastolic Limits: 120 mmHg high, 30 mmHg low
  • Inflation Pressure: 160 mmHg (adult/ped); 110 mmHg (neonate)
  • Cycle Button Interval: 15

SpO2

  • Measurement Range: 10 to 100%
  • Pulse Rate Range: 20 to 250 beats/min
  • Accuracy (Adult, no motion): 70 to 100% ±2 digits
  • Accuracy (Neonate, no motion): 70 to 100% ±3 digits
  • Accuracy (With Motion): 70 to 100% ±3 digits
  • Low Perfusion: 70 to 100% ±2 digits; 0 to 69% unspecified
  • Pulse Rate Accuracy Without Motion: 20 to 250 beats/min ±3 digits
  • Pulse Rate Accuracy With Motion: 55 to 125 beats/min ±5 digits
  • Pulse Rate Low Perfusion: 20 to 250 beats/min ±3 digits
  • Pulse Rate Limits: High 150; Low 50

Temperature

  • Predictive Mode Range: 35.6°C to 41.1°C (96.0°F to 106.0°F)
  • Monitor Mode Range: 26.7°C to 41.1°C (80.0°F to 106.0°F)
  • Monitor Mode Accuracy: ±0.1°C (±0.2°F) when tested in a calibrated liquid bath
  • Determination Time: Approximately 10 seconds, typical

Physical

  • Height: 9.7 inches (24.7 cm)
  • Width: 8.6 inches (21.9 cm) without temperature; 10 inches (25.4 cm) with temperature
  • Depth: 5.3 inches (13.5 cm)

Standards

  • Blood Pressure Standard: Meets or exceeds ANSI/AAMI SP-10