Penlon Sigma Delta Anesthetic Vaporizer – Sevoflurane
The Penlon Sigma Delta delivers consistent sevoflurane concentrations even when fresh gas flows drop below 1 L/min, where many vaporizers start losing accuracy.
Quality Management
Facility & Processes
Biomedical Technicians
About the Penlon Sigma Delta Anesthetic Vaporizer – Sevoflurane
The Penlon Sigma Delta delivers consistent sevoflurane concentrations even when fresh gas flows drop below 1 L/min, where many vaporizers start losing accuracy. This matters during low-flow anesthesia protocols where precise agent delivery becomes critical for both patient safety and cost control.
Unlike older vaporizer designs that require frequent recalibration, the Sigma Delta maintains output accuracy across its entire flow range without operator adjustments. The short version: it works reliably at the flows your anesthesiologists actually want to use. You’ll see fewer concentration alarms and more predictable wake times.
At 4.8 kg, it’s lighter than most competing sevoflurane vaporizers, and the service-free design means ten years between major maintenance cycles. Worth noting that both key-fill and pour-fill configurations are available, so you can match your department’s existing workflow.
Key Features
- Reliable performance at low fresh-gas flows
- Compatible with Selectatec®, Drager Plug-In®, North American Drager, and Cagemount systems
- Lightweight construction for easy handling
- Service-free operation with 10-year service intervals
- Available in key-fill or pour-fill models
Specifications for Penlon Sigma Delta Anesthetic Vaporizer – Sevoflurane
Weight
- Weight: 4.8 kg approx.
Sizes
- Mounting Dimensions (Cagemount): 133 mm wide × 158 mm deep × 219 mm high
- Mounting Dimensions (Selectatec® Compatible, with Interlock): 120 mm wide × 190 mm deep × 242 mm high
- Mounting Dimensions (Drager Plug-In® Compatible): 100 mm wide × 190 mm deep × 242 mm high
Capacity
- Volume at Max Mark: 250 mL nominal
- Volume at Min Mark: 35 ±10 mL
- Residual After Draining: Approximately 60 ±10 mL retained by wick
Performance
- Flow Range: Operating flow range 0.2 to 15 litres/min
- Temperature Range: Operating temperature range 15° to 35°C (58° to 95°F)
Materials
- Components: Plastic
Compatibility
- Mounting Systems: Selectatec®, Drager Plug-In®, North American Drager, Cagemount
Intended Use
- Primary Use: Delivery of sevoflurane on anesthesia workstations
Standards
- Trademark Notes: Selectatec® is a Datex Ohmeda Trademark; Plug in® is a Drager Trademark