DRE Waveline Nano CO2

Brand: DRE
Web ID: 11864
Product Number: 60G100: International for medical (use on humans) facilities, with Sidestream CO2 (human probe) 60G100V: For Vet facilities, with Mainstream CO2 (vet probe) 60G100VS: For Vet facilities, with sidestream CO2 (vet probe)

0 item is in your cart. View cart now

Need help choosing?

Ask an Equipment Expert

(502) 244-4444

Listing Terms & Conditions

All product and company names are trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement or sponsorship by them.

Details

Lightweight patient monitor delivers multi-parameter measurements in any care environment.

The DRE Waveline Nano CO2 is a portable multi-parameter monitor intended for use with adult, pediatric and neonatal patients. Designed to fit in the palm of your hand, the DRE Waveline Nano CO2 allows clinicians to measure SpO2, pulse rate, EtCO2 and Respiration in any care environment — including emergency transport, intensive care units and outpatient facilities.

Available in mainstream or sidestream configurations. For more information on the DRE Waveline Nano CO2, contact a DRE Representative today.

Features

  • Portable, multi-parameter monitor measures SpO2, pulse rate, EtCO2 and RESP.
  • Suitable for use with adult, pediatric and neonatal patients.
  • Available in mainstream or sidestream configurations.
  • Lightweight design fits in the palm of your hand and easily transitions from transport to emergency rooms, ICU’s and outpatient clinics.
  • Two measuring modes:
    • Monitor mode: continuously stores and measures data.
    • Spot-check mode: intermittent measurements.
  • Easy-to-read, user-intuitive LCD display panel shows real time trend measurements.
  • Display panel rotates for clear readings in vertical or horizontal positions.
  • Customizable alarm limits for SpO2, pulse rate and EtCO2.
  • Adjust volume of alarm and alert audible tones.
  • Comes standard with patient information management and a data line for storing, reviewing and analysis.
  • Battery life rated for approximately six hours.
  • Uses four standard AA alkaline or Ni-MH batteries.

Standard Configuration

  • Vital Signs Monitor
  • Adult Finger SpO2 Sensor
  • EtCO2 Module
  • Adult Airway Adapter
  • Pediatric Airway Adapter
  • DB9 Adapter Cable
  • Hanging Strap
  • Operation Manual

Specifications

Dimensions

  • Width: 2.95 in (75 mm)
  • Height: 5.31 in (135 mm)
  • Depth: 1.1 in (28 mm)
  • Weight: 9.1 oz (258 g) with battery

General

  • Type of Protection Against Electric Shock: Internally Powered
  • Mode of Operation: Continuous
  • Degree of Protection Against Ingress of Liquids: IPX1, drip proof
  • Degree of Mobility: Portable
  • Degree of Protection Against Electric Shock: Type BF
  • Safety Requirements: EN60601-1:1990

Parameters

  • SPO2 Range: 0-100%
  • SPO2 Accuracy: ±2 at 70-100% <70%, undefined
  • SPO2 Resolution: 1%
  • EtCO2 Range: 0-20% (0 - 150 mmHg)
  • EtCO2 Accuracy: ±2 mm Hg @ <5.0% CO2 (at BTPS) | <10% of reading @ >5.0% CO2 (at BTPS)
  • EtCO2 Resolution: 1 bpm
  • Pulse Rate Range: 25 - 250 bpm
  • Pulse Rate Accuracy: ±2 at 25 - 250 bpm
  • Pulse Rate Resolution: 1 bpm
  • RR Range: 0-150 (BPM)
  • RR Accuracy: ±1 bpm
  • RR Resolution: 1 bpm

Alarm Defaults

  • SpO2 Adult: 99 (high) - 92 (low)
  • SpO2 Pediatric: 99 (high) - 92 (low)
  • SpO2 Neonatal: 99 (high) - 92 (low)
  • PR Adult: 100 (high) - 60 (low)
  • PR Pediatric: 110 (high) - 70 (low)
  • PR Neonatal: 120 (high) - 80 (low)
  • EtCO2 Adult: 40 (high) - 30 (low)
  • EtCO2 Pediatric: 40 (high) - 30 (low)
  • EtCO2 Neonatal: 40 (high) - 30 (low)
  • RR Adult: 30 (high) - 8 (low)
  • RR Pediatric: 30 (high) - 8 (low)
  • RR Neonatal: 30 (high) - 8 (low)

Power

  • AC power supply 100-240 VAC, 47-63Hz
  • Or four standard “AA” alkaline or Ni-MH cells (IEC Type LR6)

Battery Life

  • Alkaline Cells: approximately 6 hours

Environmental

  • Operating Humidity: 30 to 95% (operating)
  • Storage Humidity: 10 to 95% (storage)
  • Shipping Humidity: 0 to 95% (shipping)
  • Operating Temp: 0 to 45°C
  • Storage Temp: -40 to +55°C