Process
The medical waste sterilizers operate with the technology of a high vacuum steam environment; with steam as the sterilization agent, operating at a pressure of up to 33PSI (2.3 bars) and a temperature of up to 279°F (137°C). Due to the unique design and special construction of the autoclave, together with the regulations requiring a minimum sterilization of 30 minutes, the sterilization cycle is relatively short, the entire cycle is no more than about 50 minutes.
Constructed of heavy-duty 316L-grade stainless steel, both single and double door models are available.
Constructed of heavy-duty 304L grade stainless steel.
Stainless steel and brass. The valves are ball piston type, self cleaning and pneumatically operated.
Can be supplied in one of the following mounting alternatives: Built-in, wall mounted, Free-standing and Pit-mounted (floor loading).
The chamber is supplied with two rails for easy loading. A variety of stainless steel loading equipment is available for your selection.
The sterilizers can be supplied with one or two doors. The door's can be fully automatic vertically sliding, horizontally sliding, or hinged with automatic locking. All door types are equipped with special safety device features that prevent the doors from opening while in operation.
The Medical Waste (BH) sterilizer control system is based on "state-of-the-art" microcomputer technology, guaranteeing high reliability and safe operation. Intervention is unnecessary after selecting the parameters and pressing the start button. The main cycle phases and the machine's actual parameters are displayed on the LCD panel during the cycle progress. The main physical parameters of the process, i.e.temperature, pressure, time and jacket pressure are controlled and displayed. The control system is easy to use and programmable. Calibration of the system can be per formed digitally from the control panel or through a computer communication port via a PC.
For a clear and concise documentation of cycle process, the control unit is provided with a 24 character per line printer, which is connected to the microprocessor. In case of an uncompleted cycle, the printout will indicate the cycle failure and the cause of the failure. An additional graphic printer is available,RS485/RS232 PC and Advanced PC Windows-based software for monitoring, logging and control is also available. A circular or trace strip chart temperature and pressure recorder can be supplied on request.
The (BH) Medical Waste system is designed to dispose of all your infectious waste in an efficient, safe, environmentally friendly and cost effective manner. In compliance with the various international regulations, the following important factors were considered in the Medical Waste (BH: Bio Hazard) Sterilization System development.
The (BH) Medical Waste sterilizer operates with saturated steam as the sterilization agent; operating at a pressure of up to 33PSI (2.3 bars) and a temperature of up to 279°F (137°C). While more and more critical diseases are evolving Tuttnauer autoclaves supply the higher level of sterilization they require.
The High vacuum sterilization method substantially shortens the sterilization cycle, achieved by evacuating the air with a vacuum pump, combined with steam pulsing. A 0.2 µm. HEPA Filter is provided to filtrate the air, which equalizes the vessel pressure. The remaining residue, which is typically substantially less then the original volume, is sterile and may be discarded as municipal waste. Tuttnauer offers a large range of the Medical Waste (BH) system, from standard 250L up to 4,000L volume, as well as varied sterilizer chamber dimensions according to the specific requirements up to 20,000 liter chambers.
The sterilizers are manufactured in accordance with A.S.M.E. standards (American Society of Mechanical Engineers), TUV – (German Standards for pressure vessels), The Medical Waste (BH) sterilizer models meet the provisions of the Medical Device Directive, as well as the Pressure Equipment Directive. In addition, the Quality System is certified in compliance with ISO 9002,EN 46002 and ISO 13488. The devices are UL Listed, comply with the FDA (Food and Drug Administration) guidelines and CE marked.
The high demands for product sterility, and personnel safety, are met by the application of automated material handling systems. Tuttnauer offers a product range of automated material handling systems, from a simple loading push/pull system, to highly automated solutions. Proven production operation and years of experience have lead to the design of safe, dependable, high throughput, material handling equipment. The loading automation development was designed side by side with our sterilization systems. This close relationship ensures that material handling is not just an after thought, but an essential component in the layout and design of your facility